8000LPH Reverse Osmosis Pure Water Plant
1. Model: JFRO-8000L
2. ISO9001 & CE certified
3. Capacity: 8000liter/hour
4. Desalination rate: 99%
5. Recovery rate: 75%
6. Membrane size: 8040
7. Control type: Auto
8. Applicable industries: Hotels, Food & Beverage factory, Farms, Restaurant,Water shop
9. Pre-shipment testing: Provided
10. Installation guidance: Online Video meeting
11. Warranty: 12 months
12. Package: Wooden case
13. Export market: United States, Spain, Poland, Italy, Australia, Canada, Mexico, Philippines, Peru, Saudi Arabia, Jamaica, Columbia, Chile, Peru,Bolivia, Argentina,Indonesia,Malaysia,Vietnam, Nigeria, Tanzania, Kenya, Morocco,Kyrgyzstan, Russia
What is the requirements for feeding water?
JUFU water 1000lph anti-fouling reverse osmosis system can treat the incoming feed water with 2000ppm<TDS<5000ppm. No matter the water is coming from borehole, well, river.. if the water’s 2000ppm<TDS<5000ppm, you can directly choose our anti-fouling RO type.If your water TDS above the range, there are still other options to handle your water, contact our sales engineer, the right model will be recommended to solve your water problem.
Do I really need a pretreatment System?
Pretreatment system can be a double guarantee for any water treatment system. By removing contaminants from water before it is treated, pretreatment can help to improve the efficiency, lifespan, and safety of the system. If you’re not sure about the right pretreatment for your case, you can send your water test report or at least a TDS value to Jufu Water, our professional sales team will design a proper pretreatment solution to partner with your RO.

The working flow chart of commercial reverse osmosis system

Specification of 8000LPH reverse osmosis system
| Model | JFRO-8000L | ||
| Producing Capacity | 8000L/H | RO membrane | 8″ |
| Recovery Rate | ≥75% | Power Supply | Single-phase: 110/120/220V 50/60Hz |
| Operating Pressure | 0.5-1.0MPa | Tri-phase: 110/220/380/415V 50/60Hz | |
| Desalination Rate | 99% | Power Consumption | 10kW |
| Filtration Accuracy | 0.0001 micron | Control Type | Manual control / Auto control |
| Feed Water Quality | SDI<5 Free Chlorine Concentration<0.1mg/L TDS<2000mg/L | ||
| Features | Removes impurities such as inorganic ions, bacteria, viruses, organic matter and colloids from raw water. | ||
What benefits reverse osmosis can bring?
High Purity Water: Reverse osmosis can filter most of the contaminants,remove impurities, dissolved solids, heavy metals and bacteria. It can treat water to high quality which can meet the safety and required standard for us.
Customizable filtration: Revese osmosis system can be designed based on your actual raw water and your final applications, the proposal can be customized to eliminate each single stage to meet your water use target.
Easy maintenance:JUFU water’s reverse osmosis system with compact design and stable performance can provide maximum comfort and worry-free experience for users.
Environmentally friendly: Sustainable use by reverse osmosis system can reduce reliance on external water supply, can make water use in a green cycle.
What is special from JUFU water?
JUFU water cares more about user experience, stable performance and worry-free after-sales service for our valued clients.
- Optimized design and Solid stainless steel Skid
- Prioritize well-known brands for key components, like DOW, Grundfos
- Adaptable to various working conditions with stable performance
- Maximum utility at minimum cost
- Rigorous factory pre-shipment testing
What consumbles I may need for long term use?
Quartz sand: remove suspended solids, organic matter, colloidal particles, microorganisms, chlorine, odor and some heavy metal ions effectively.Change the filter media every 2 years
Activitated carbon: remove color, odor, residual chlorine and irganics, change the filter media every 2 years
Water softener: exchange ions of calcuym and magnesium,change the filter media every 2 years
What FACTORS will influnce the cost of Commercial reverse osmosis system?
Commercial reverse osmosis is not a one-size-fits-all system, it can be flexible to change according to the raw water in different working site.
Comprehensive blending system can be more effective in solving water problems.for example: PH dosing, scale inhibitor dosing,chemical dosing …
Here listed several factors that can influnence the costs:
1. Capacity of the commercial reverse osmosis system, lower producing capacity cost lower investment. The bigger the flowrate, the higher the cost;
2. Raw water quality will be the key factors in terms of water solution.Different TDS, conductivity, PH and hardness will be solved by different combinations, the cost will be influnenced accordingly;
3.Required purity of treated water.The tougher the standard, the higher the price will be;
4.Materials and key components applied to produce commercial reverse osmosis system. Solid skid and durable components ensure good operation of the product;
5.Advanced control system including touchscreen, PLC control, wifi connection.