sales@jufuwater.com +8618001362005
1000LPH RO Drinking Water Treatment Equipment
1. Model: JFRO-1000L
2. ISO9001 & CE certified
3. Capacity: 1000liter/hour
4. Desalination rate: 99%
5. Recovery rate: 75%
6. Membrane size: 4040
7. Control type: Auto
8. Applicable industries: Hotels, Food & Beverage factory, Farms, Restaurant,Water shop
9. Pre-shipment testing: Provided
10. Installation guidance: Online Video meeting
11. Warranty: 12 months
12. Package: Wooden case
13. Export market: United States, Spain, Poland, Italy, Australia, Canada, Mexico, Philippines, Peru, Saudi Arabia, Jamaica, Columbia, Chile, Peru,Bolivia, Argentina,Indonesia,Malaysia,Vietnam, Nigeria, Tanzania, Kenya, Morocco,Kyrgyzstan, Russia
What is the requirements for feeding water?
JUFU water 1000lph standard reverse osmosis system can treat the incoming feed water with TDS<2000ppm. No matter the water is coming from borehole, well, river.. if the water’s TDS<2000ppm, you can directly choose our standard RO type.If your water TDS above the range, there are still other options to handle your water, contact our sales engineer, the right model will be recommended to solve your water problem.
Do I really need a pretreatment System?
Pretreatment system can be a double guarantee for any water treatment system. By removing contaminants from water before it is treated, pretreatment can help to improve the efficiency, lifespan, and safety of the system. If you’re not sure about the right pretreatment for your case, you can send your water test report or at least a TDS value to Jufu Water, our professional sales team will design a proper pretreatment solution to partner with your RO.

How your pretreatment system designed?
The pretreatment system normally include:Quartz sand filter, Activated carbon filter and water softener.
Quartz sand filter Remove suspended solids, organic matter, colloidal particles, microorganisms, chlorine, odor and some heavy metal ions.
Activated carbon filter Remove rust; sediment; organic compounds that impart taste, odor or color; chlorine and some other contaminants.
Water Softener Remove calcium, magnesium, and other minerals from water.
Work flow chart

Specification of 1000LPH reverse osmosis system
| Model | JFRO-1000L | ||
| Producing Capacity | 1000L/H | RO membrane | 4” |
| Recovery Rate | ≥75% | Power Supply | Single-phase: 110/120/220V 50/60Hz |
| Operating Pressure | 0.5-1.0MPa | Tri-phase: 110/220/380/415V 50/60Hz | |
| Desalination Rate | 99% | Power Consumption | 3kW |
| Filtration Accuracy | 0.0001 micron | Control Type | Manual control / Auto control |
| Feed Water Quality | SDI<5 Free Chlorine Concentration<0.1mg/L TDS<2000mg/L | ||
| Features | Removes impurities such as inorganic ions, bacteria, viruses, organic matter and colloids from raw water. | ||
What is the uniqueness of reverse osmosis system?
In the development of water treatment industry, reverse osmosis systems become most effective and mature technology to help human being to treat water at high efficiency, low energy consumption and affordable price. JUFU Water designed series of commercial reverse osmosis systems to carefully handle different water, different needs and different working conditions, we care each single unit!
What is special from JUFU water?
JUFU water cares more about user experience, stable performance and worry-free after-sales service for our valued clients.
- Optimized design and Solid stainless steel Skid
- Prioritize well-known brands for key components, like DOW, Grundfos
- Adaptable to various working conditions with stable performance
- Maximum utility at minimum cost
- Rigorous factory pre-shipment testin
The details of 1000LPH reverse osmosis system

What FACTORS will influnce the cost of Commercial reverse osmosis system?
Commercial reverse osmosis is not a one-size-fits-all system, it can be flexible to change according to the raw water in different working site. Comprehensive blending system can be more effective in solving water problems.for example: PH dosing, scale inhibitor dosing,chemical dosing …
Here listed several factors that can influnence the costs:
1. Capacity of the commercial reverse osmosis system, lower producing capacity cost lower investment. The bigger the flowrate, the higher the cost;
2. Raw water quality will be the key factors in terms of water solution.Different TDS, conductivity, PH and hardness will be solved by different combinations, the cost will be influnenced accordingly;
3.Required purity of treated water.The tougher the standard, the higher the price will be;
4.Materials and key components applied to produce commercial reverse osmosis system. Solid skid and durable components ensure good operation of the product;
5.Advanced control system including touchscreen, PLC control, wifi connection.
The working process of commercial reverse osmosis system.
Raw water coming from tap, boreholes and rivers, they all have impurities before treatment. When you apply pressure to a highly concentrated solution, which causes the solvent to pass through a semipermeable membrane to the lower concentrated solution. This leaves behind a higher concentration of solute on one side, and pure solvent on the other.
What kind of matters can reverse osmosis filter out?
Reverse osmosis system can take salts, Dissolved Organics, bacteria, Macromolecular organics, particles and silts from water and filter into pure water.

What benefits reverse osmosis can bring?
High Purity Water: Reverse osmosis can filter most of the contaminants,remove impurities, dissolved solids, heavy metals and bacteria. It can treat water to high quality which can meet the safety and required standard for us.
Customizable filtration: Revese osmosis system can be designed based on your actual raw water and your final applications, the proposal can be customized to eliminate each single stage to meet your water use target.
Easy maintenance:JUFU water’s reverse osmosis system with compact design and stable performance can provide maximum comfort and worry-free experience for users.
Environmentally friendly: Sustainable use by reverse osmosis system can reduce reliance on external water supply, can make water use in a green cycle.
What consumbles I may need for long term use?
Quartz sand: remove suspended solids, organic matter, colloidal particles, microorganisms, chlorine, odor and some heavy metal ions effectively.Change the filter media every 2 years
Activitated carbon: remove color, odor, residual chlorine and irganics, change the filter media every 2 years
Water softener: exchange ions of calcuym and magnesium,change the filter media every 2 years

Considerations for the implementation of reverse osmosis system
Various factors need to be considered to maximize the best effect for the reverse osmosis system.
Requirements and regulations: Compehensively understand the final goal of the project, implement the project with relevant regulations and standards.
Practical application of working conditions: Each design should be considered based on real situation on the working site: temperature,humidity,working hours and peak hour capacity. The system should be designed to satisfy each single scenario.
System control: Automatic and continuously monitor the system to make sure the water treatment tasks are all in compliance
Design and Maintenance:Consider all possible issues during product design, including water flow, feed water quality, routine maintenance.